Technical Details - Properties Of Fire Retardant ACP Sheets

Properties Of Fire Retardant ACP Sheets

STANDARD SUBJECT RESULT
SYSTEM TEST
NFPA 285 ISMA Test -Intermediate-Scale Multistory Apparatus, façade fire test standards for evaluation of fire propagation characteristic of exterior non load bearing wall assemblies contain combustibles comp[ounds Passed, (No flames into second floor, Externally flame shall not reach 10 ft. height on top of window and 5 ft. laterally centre of window & thermocouples inside of the wall assembly shall not exced 1000°F during test.)
ASTM E 119 -16 Test standard for wall partition assemblies are considered fire barrier system, temperature control and withh special framing system is part of wall 120 minutes , Pass
REACTION O FIRE TEST
EN 13501 -1 – 2018 Single burning and reaction to fire B – s1, d0
ASTM D 1929 – 16 Determining Ignition Temperature of Plastics Spontaneous Ignition Temperature:
STI: 452°C (842°F)
Flash Ignition Temperature:
FTI: 429°C (824°F)
ASTM E 84 – 15a Surface Burning Characteristics of Building Materials Flame Spread Index: 0
Smoke Developed Index: ≤ 5
BS 476 Part 6 & 7 Surface spread of flame  & flame propagation Class 0  classification
DIN4102 Standard Method of Fire Test of Exterior Wall Assemblies FR B1, Passed

Test